Fi-Fi CLASS REQUIREMENT

Fire fighter 1 ( or 2 or 3 ) are class notations granted to vessels built and equipped in compliance with the relevant class requirements. These requirements are based upon experience and an appraisal of future vessels, size of object to be protected and available fire fighting equipment.

The following matters are covered by the classification:
• The vessel's fire fighting capability.
• The vessel's stability and its ability to keep position when the fire fighting monitors are in operation.
• The vessel's ability for self protection.

Class
Notation
FiFi1
FiFi2
FiFi3
No. of
Monitors
2
2
(DNV)
3
4
3
4
Monitor
capacity
(m3/h)
1200
3600
2400
1800
3200
2400/
2500

No. of
Pumps

1-2
2
2-4
2
2-4

Total
pump
capacity

(m3/h)

2400
7200
7200
9600
9600/
10000

Throw
length

(m)

120
180
(from bow)
150
180
(From bow)
150
Throw height (m)
45
110 at 70m
70
110 at 70m
70